Najważniejsze informacje
Specyfikacja
Najczęściej zadawane pytania
Opinie
 

Przegląd produktu

 

Specyfikacja

Model:

ICC-510

Input:
100~240V AC 50/60Hz 10A MAX
Output:
100~240V AC 50/60Hz 10A MAX
Dimension:
Sensor: 4.1 x 4 x 1.7 inches / 10.3 x 10.2 x 4.3 cm

Controller: 2.8 x 6.4 x 1.4 inches / 7.2 x 16.2 x 3.5 cm

Socket (US): 3.54 x 1.66 x 1.13 inches / 9 x 4.2 x 2.87 cm
Cable Length:
Sensor: 78.7 inches / 200 cm

Controller: 59 inches / 150 cm

Cable: 13.78 inches / 35 cm
Weight:
583 g / 1.29 lbs / 20.6 oz
CO2 Measurement Range:
0 to 9999 ppm
CO2 Accuracy:
±(50ppm+5%) in the range from 400 to 9999 ppm
CO2 Sampling Interval:
Every 1 sec
Sensing Method:
NDIR
Operating Temp:
32-122℉/ 0-50℃
Operating Humidity:
0 to 95 %RH (non-condensing)
Package Content:

CO2 Controller *1, CO2 Sensor *1, User Manual *1

Show More

Porównaj z innymi

Appearance:

Programmable CO2 Controller with S01 Sensor ICC - 510 - INKBIRD Programmable CO2 Controller with S01 Sensor ICC - 500T - INKBIRD
Model:

ICC-510

ICC-500T

Other Product

Input Power: 100~240V AC 50/60Hz 10A MAX 100~240V AC 50/60Hz 10A MAX 100~240V AC 50/60Hz 5A MAX
Output Power: 100~240V AC 50/60Hz 10A MAX 100~240V AC 50/60Hz 10A MAX 100~240V AC 50/60Hz 5A MAX
Sensing Method: NDIR NDIR NDIR
Measurement Range: 0-9999 ppm 0-9999 ppm 0-3000 ppm
Sensor Warranty: 5 years 5 years 1 year
Controller Warranty: 2 years 2 years 1 year
Calibration: General + Professional General General
Sampling Interval: 1 sec 120 sec 120 sec
Operating Mode:

Plant with Fan / Plant without Fan / Human

/

/

 

Najczęściej zadawane pytania

What is the warranty period for ICC-510?

INKBIRD provides a warranty that exceeds industry standards for the ICC-510, with a 5-year warranty on the sensor and 2 2-year warranty on the controller.

Can ICC-510 be used with different CO2 systems?

Yes, the ICC-510 is flexible and can be integrated with a variety of CO2 delivery systems like CO2 tanks, generators, and compressed air units. Just make sure that the CO2 source is compatible with the controller setup.

What maintenance does ICC-510 require?

Regularly check the sensor for any dust or debris that could affect its performance and clean it when needed. It's also recommended to calibrate the CO2 sensor at least once a year to ensure its accuracy. Store the CO2 controller in place with the temperature of 32℉~140℉/0℃~60℃, and humidity of 20~80%RH (no ice or condensation).

What is the ideal CO2 level for plant growth?

Ideal CO2 levels for most plants are generally between 1000 and 1300 ppm. However, every setup and environment varies, which means you'll need to adjust the ICC-510 based on the specific needs of your plants and their surroundings.